BJWDV - 5155 ALUMINUM COATING CEMENT
- MSDS: BJWDV
- Manufacturer: GIBSON HOMANS CO
- Product Name: 5155 ALUMINUM COATING CEMENT
- National Stock Number: 8030-00F013998
Product Identification
Product ID:5155 ALUMINUM COATING CEMENT
MSDS Date:05/19/1987
FSC:8030
NIIN:00F013998
MSDS Number: BJWDV
Responsible Party
TWINSBURG, OH 44087-5000
US
Emergency Phone: 330-425-3255/330-467-8128
Info Phone: 330-425-3255/330-467-8128
Cage: GIBS1
Contractor
Telephone: 410-391-4500/216-843-2982
Cage: GIBS1
Ingredients
STODDARD SOLVENT (PETROLEUM DISTILLATE), MINERAL SPIRITS
CAS: 8052-41-3
RTECS: WJ8925000
OSHA PEL 500 PPM
ACGIH TLV: 100 PPM
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: IRRITATION. EYES: IRRITATION &
BLURRED VISION. INHALATION: NASAL & RESPIRATION IRRITATION,
DIZZINESS, NAUSEA, POSSIBLE UNCONSCIOUSNESS & EVEN ASPHYXIATION.
INGESTION: GASTROINTESTINAL IRRITATION , NAUSEA, VOMITING &
DIARRHEA.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN: IRRITATION. EYES: IRRITATION & BLURRED
VISION. INHALATION: NASAL & RESPIRATION IRRITATION, DIZZINESS,
NAUSEA, POSSIBLE UNCONSCIOUSNESS & EVEN ASPHYXIATION. INGESTION:
GASTROINTESTINAL IRRITATION , NAUSEA, VOMITING & DIARRHEA.
First Aid
First Aid:EYES: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. SKIN:
WASH W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. GIVE
CPR/OXYGEN IF NEEDED. INGESTION: DON'T INDUCE VOMITING. OBTAIN
MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point Method:PMCC
Flash Point:100F
Lower Limits:0.8
Upper Limits:7
Extinguishing Media:FOAM, CO2, DRY CHEMICAL
Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR SELF CONTAINED
BREATHING APPARATUS. WATER MAY CAUSE FROTHING, APPLY CAUTIOUSLY.
Accidental Release
Spill Release Procedures:DIKE SPILL AREA. REMOVE SOURCES OF IGNITION.
VENTILATE AREA IF NECESSARY. RECOVER FREE LIQUID. ADD ABSORBENT TO
SPILL AREA.
Handling
Handling and Storage Precautions:KEEP AWAY FROM SOURCES OF IGNITION.
USE ONLY W/ADEQUATE VENTILATION.
Other Precautions:AVOID CONTACT W/SKIN. KEEP OUT OF REACH OF CHILDREN.
Exposure Controls
Respiratory Protection:IF >TLV, A NIOSH/MSHA APPROVED BREATHING
APPARATUS IS RECOMMENDED. NOT NORMALLY NEEDED IN WELL VENTILATED
AREA.
Ventilation:PROVIDE ADEQUATE LOCAL EXHAUST/MECHANICAL VENTILATION TO
KEEP
Eye Protection:CHEMICAL GOGGLES
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:300-315F
Vapor Pres:2
Vapor Density:>1
Spec Gravity:1.0-1.5
Evaporation Rate & Reference:(BU AC = 1): <1
Solubility in Water:INSOLUBLE
Appearance and Odor:GOLDISH TO SILVERISH LIQUID, SOLVENT ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, ACIDS & BASES
Stability Condition to Avoid:SOURCES OF IGNITION
Hazardous Decomposition Products:CO2, CO
Disposal
Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.